OTL Report No. 116-F-32-5
US
Portland
MODELS
INSTALLATION INSTRUCTIONS
SDVST Direct-Vent
Gas Fireplaces
SDVST-N-B
SDVPF-N-B
MILLIVOLT:
P/N 700037M Rev. F 01/2011
This manual is one of a set of two supporting this product.
Refer to P/N 725035M for Care and Operation Instructions.
Ce manuel est disponible en francais, simplement
en faire la demande. Numéro de la pièce 700037CF.
AVERTISSEMENT : Assurez-vous de bien suivre les
instructions données dans cette notice pour réduire au
minimum le risque d’incindie ou d’explosion ou pour
éviter tout dommage matériel, toute blessure ou la mort.
- Ne pas entreposer ni utilizer d’essence ni d’autres vapeurs
ou liquides inflammables dans le voisinage de cet appareil
ou de tout autre appareil.
- QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ :
• Ne pas tenter d’allumer d’appareil.
• Ne touchez à aucan interrupteur. Ne pas vous servir des
téléphones se trouvant dans le bâtiment où vous trouvez.
• Appelez immédiatement votre fournisseur de gaz depuis
un voisin. Suivez les instructions du fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz,
appelez le service des incindies.
-
L’installation et l’entretien doivent être assurés par un
installateur ou un service d’entretien qualifié ou par le
fournisseur de gaz.
WARNING: If the information in these instructions
is not followed exactly, a fire or explosion may
result, causing property damage, personal injury,
or death.
-
vapors and liquids in the vicinity of this or any other
appliance.
- WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any
phone in your building.
Immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s
instructions.
department.
- Installation and service must be performed by a
WARNING
/
AVERTISSEMENT
/
AVISO
HOT GLASS WILL CAUSE
BURNS.
DO NOT TOUCH GLASS
UNTIL COOLED.
NEVER ALLOW CHILDREN
TO TOUCH GLASS.
UNE SURFACE VITRÉE CHAUDE
PEUT CAUSER DES BRÛLURES.
LAISSER REFROIDIR LA SURFACE
VITRÉE AVANT D'Y TOUCHER.
NE PERMETTEZ JAMAIS À UN ENFANT
DE TOUCHER LA SURFACE VITRÉE.
EL VIDRIO CALIENTE
CAUSARÁ QUEMADURAS.
USTED DEBE NUNCA
TOCAR EL VIDRIO CALIENTE.
LOS NIÑOS DEBEN NUNCA
TOCAR EL VIDRIO.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
INSTALLATEUR : Laissez cette notice avec l'appareil.
CONSOMMATEUR : Conservez cette notice pour
consultation ultérieure.
This appliance may be installed as an OEM installation in a manufactured home (USA only) and must be
installed in accordance with the manufacturer’s instructions and the Manufactured Home Construction and
Safety Standard, Title 24 CFR, Part 3280, in the United States or the Standard for Installation in Manufactured
Homes, CAN/CSA Z240 MH, in Canada. This appliance is only for use with the type of gas indicated on the
rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.
Page view 0
1 2 3 4 5 6 ... 39 40

Summary of Contents

Page 1 - AVERTISSEMENT

OTL Report No. 116-F-32-5USPortlandMODELSINSTALLATION INSTRUCTIONSSDVST Direct-Vent Gas FireplacesSDVST-N-BSDVPF-N-BMILLIVOLT:P/N 700037M Rev. F 0

Page 2 - AVERTISSEMENT

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.10PRODUCT REFERENCE INFORMATIONCat. No.Model Ship Wt.Ship. VolumeH4633 SDVST 282 lbs 52W x 27D x

Page 3

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.11NOTES • Annual Fuel Utilization EfficiencyDiagrams, illustrations and photographs are not to sc

Page 4 - Adjustment

12NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.Also see Figures 11 and 12 on Pages 10 and 115-5/8"(143 mm)3-1/8"(79 mm)Figure 13 - RO

Page 5 - (one end flush

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.13Securing Screws(OUTSIDE OF APPLIANCE)InsulationTop VentVent Seal CapFirebox TopCabinet TopCROSS

Page 6 - Side Elevation View

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.14Figure 17TRAHCHTGNELNOITCESTNEVnoitceSlanimoN)sehcni(htgneL621426384TOTALQTYnoitceSteN)sehcni(ht

Page 7 - Figure 5

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.15Figure 18Roof FramingCeilingFramingPlumbBob10-1/2" Min. (267 mm)10-1/2" Min. (267 mm)F

Page 8

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.BlockingSupport Straps(Plumber's tape)8 feet (2.4 m)Maximum1 inch (25.4 mm) minimum clearance

Page 9

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.17Framing Dimensions for RoofInches (millimeters)Pitch C D0/12 10-1/2 in.(267 mm)10-1/2 in.(267 mm

Page 10 - Figure 11

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.18HVV1VHFigure 29 - Side Vent - ONE 90 DEGREE ELBOWFigure 30 - Top Vent - TWO 90 DEGREE ELBOWS

Page 11 - Figure 12

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.19H1VV1HVH1HV1u Ceiling Firestop / Spacer (SV4.5VF)vWall Firestop/Spacer (SV4.5HF)Table CH+H1 Maxi

Page 12 - Step 2. ROUTING GAS LINE

2TABLE OF CONTENTS Packaging ...Page 2Introduction ...Page 2General Informa

Page 13 - (INSIDE of

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.20HORIZONTAL (OUTSIDE WALL) TERMINATION SYSTEMSee Figure 33, and Figures 36 to 41 (Pages 22 to 24)

Page 14 - Figure 17

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.21It is important to maintain the required clear-ances to combustibles: 1" (25 mm) at all sid

Page 15 - Figure 20

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.22 WARNINGUnder no circumstances, may separate sections of concentric flexible vent pi

Page 16 - (122 mm)

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.23H1VHu Ceiling Firestop / Spacer (SV4.5VF)vWall Firestop/Spacer (SV4.5HF)Table FH+H1 Maximum H Ma

Page 17 - Figure 26

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.24Table IH + H1 Maximum V Minimumfeet (meter) feet (meter)5 (1.524)Elbow Only5 (1.524) 1 (0.305)10

Page 18 - H = 8 feet (2.4 meters) Max

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.25D. Install Firestop / Spacers at ceilings and walls - When Secure Flex penetrates a wall or ceil

Page 19

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.26Step 4. FIELD WIRING Note: The gas valve is set in place and pre-wired at the factory.A. SIT and

Page 20 - Page 16 for vertical vent

27Step 5. WIRING - OPTIONAL FORCED AIR BLOWER (FBK-100) (See Figure 45) - An optional ON/Off (FRS) control switch is also available (installs on brack

Page 21 - For thicknesses greater than

28NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.Step 6. CONNECTING GAS LINE All codes require a shut-off valve mounted in the supply line. The

Page 22 - H = 20 ft. (6.096 m) Max

29NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.Turn on gas supply and test for gas leaks using a gas leak test solution (also referred to as bu

Page 23 - = 20 ft. (6.096 m) Max

3The appliance, when installed, must be electri-cally grounded and wired in accordance with local codes or, in the absence of local codes, with the Na

Page 24 - Elbow Only

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.30Figure 52BURNER POSITIONINGREAR BURNERFRONT BURNERPILOTBURNERNote: The burners are not identical

Page 25 - Figure 43

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.31Step 9. INSTALLATION AND REMOVAL OF GLASS DOORRemoving Glass Enclosure Panels(see Figure 55)

Page 26 - Showing the Blower Wiring

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.32Figure 57 - Burner Flame Appearance1. Locate adjustment rod and adjust air shutter to the stan

Page 27 - CAUTIONS

33Step 12. ATTACHING SAFETY-IN-OPERATION WARNINGSIt is the installer's responsibility to ensure these warnings are properly affixed during install

Page 28 - Gas Flex Line Connector

34Item Cat. No. Model Description1 H1968 SV4.5HT-2 Horizontal Square Termination With Firestop / spacer (H2246) & Adapter (74L61)2 H2152 SV4

Page 29

35222319Sealant20Item Cat. No. Model Description18 H1969 SF4.5HT-2 Horizontal Square Termination (without flex)18 77L87 SFKIT12S Flex Square Term. (wit

Page 30 - Figure 51

36NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.Item Cat. No. Model Description24 92L07 SV-MHPK1 Manufactured Home Pipe Kit (SV) - 1/12 Pitch24

Page 31

37NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.Natural Gas to Propane GasConversion KitsFireplaceTypeCat. No.(model)Millivolt85L65FGCK-DMOMNPPr

Page 32 - WARNINGS

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.38SIT Millivolt Gas ValvePilot for SIT Millivolt Gas ValveFigure 61PressureRegulatorRemove These C

Page 33

39NOTES

Page 34 - INSTALLATION ACCESSORIES

4NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.Inlet Gas Supply Pressure(all models)Fuel # Minimum MaximumNatural Gas5.0" WC(1.24 kPa)10.5&

Page 35 - , 10 Pack

Printed in U.S.A. © 2006 Lennox Hearth ProductsP/N 700037M REV. F 01/2011Lennox Hearth Products reserves the right to make changes at any time, wi

Page 36

5NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.COLD CLIMATE INSULATIONFor cold climate installations, seal all cracks around your appliance with

Page 37

6NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.VENT TERMINATION CLEARANCESThese instructions should be used as a guideline and do not supe

Page 38 - THEN FRONT BURNER

7VENT TERMINATION CLEARANCESFigure 5NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALEEXTERIOR HORIZONTAL VENT TERMINATION CLEARANCE REQUIREMENTS Canadia

Page 39

8NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.5 (127)8-1/4(20 9)14(356)12 (30 5)19 (48 3)4 (102)2(51)4(102)6(152)8(203)10(254)12(305)6 (152)10

Page 40 - P/N 700037M REV. F 01/2011

9NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.TYPICAL INSTALLATION SEQUENCEThe typical sequence of installation is outlined below. However,